Tezin Türü: Yüksek Lisans
Tezin Yürütüldüğü Kurum: Orta Doğu Teknik Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü, Türkiye
Tezin Onay Tarihi: 2010
Öğrenci: EFE GÖKÇE KURT
Danışman: ERDEM CANBAY
Özet:Pseudo-dynamic testing was employed to observe the seismic performance of three different retrofit methods on two story three bay reinforced concrete frame structures. The three test frames have hollow clay tile (HCT) infills in the central bay. All of the test frames represent the seismic deficiencies of the Turkish construction practice such as use of plain reinforcing bars, low strength concrete and insufficient confining steel. Two non-invasive and occupant friendly retrofit schemes suggested in the Turkish Earthquake Code, namely use of Fiber Reinforced Polymers and precast concrete panels integrated on the HCT infills and traditional approach of adding concrete infill wall were employed. Specimens were subjected to three different scale levels of North-South component of Duzce ground motion. Reference specimen experienced severe damage at 100% scale level and reached collapse stage due to the loss of integrity of the infill wall and significant damage on the boundary columns. The retrofitted test structures were able to survive the highest level 140% Duzce ground motion. Test results confirmed the success of the retrofit methods for simulated earthquake loads.