Tezin Türü: Yüksek Lisans
Tezin Yürütüldüğü Kurum: Orta Doğu Teknik Üniversitesi, Fen Bilimleri Enstitüsü, Türkiye
Tezin Onay Tarihi: 2019
Tezin Dili: İngilizce
Öğrenci: BORA OKAN
Asıl Danışman (Eş Danışmanlı Tezler İçin): Ayşegül Aksoy
Eş Danışman: Tuba Hande Bayramoğlu
Özet:With increasing population and developing regulations, wastewater treatment plants (WWTP) have started to become a higher energy consuming sector in order to serve higher capacities. In the design and management phases of a treatment plant, energy consumption and carbon footprint of the plant should be considered. In this regard, hypothetical and real case models are created to simulate and compare WWTP systems. In this thesis study, first, municipal WWTPs of Turkey were analyzed to determine the traditional technologies concerning biological treatment and sludge stabilization of municipal wastewaters. Combinations of different units and processes were used to build 105 hypothetical WWTP models. These models were then used to determine sludge production amount, energy consumption, and carbon footprint. It was observed that specific energy consumption ranged between 0.002 kWh/m3 and 0.89 kWh/m3, while, carbon footprints varied between 588 kgCO2eq/h and 5,697 kgCO2eq/h. In addition, Bursa East Domestic WWTP was considered for the simulation-based optimization of a real WWTP. It was shown that both energy consumption and carbon footprint of this treatment plant can be reduced by 10%.