Tezin Türü: Yüksek Lisans
Tezin Yürütüldüğü Kurum: Orta Doğu Teknik Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü, Türkiye
Tezin Onay Tarihi: 2008
Tezin Dili: İngilizce
Öğrenci: Mehmet Ağar
Danışman: MUSTAFA UĞUR POLAT
Özet:Structures in high seismic risk areas may be susceptible to severe damage in a major earthquake. Structures designed to meet older code requirements may be at even greater risk. When these structures are evaluated with respect to current code criteria, it is observed that they lack of lateral strength and/or ductility. Since safety and economic considerations are major problems, these structures become viable candidates for retrofit and seismic strengthening. For the variety of structures and possible deficiencies that arise, several retrofitting techniques can be considered. Diagonal bracing system is one of the retrofitting techniques and it provides an excellent approach for strengthening and stiffening existing building for lateral forces. Also, another potential advantage of this system is the comparatively small increase in mass associated with the retrofitting scheme since this is a great problem for several retrofitting techniques. In this study, the use of steel bracing for the strengthening of low, intermediate, and relatively high rise reinforced concrete frames are investigated analytically. The ultimate lateral load capacities of the strengthened frames are determined by a load controlled push-over analysis. The post-tensioning effect of preloading is also investigated.