Tezin Türü: Yüksek Lisans
Tezin Yürütüldüğü Kurum: Orta Doğu Teknik Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü, Türkiye
Tezin Onay Tarihi: 2013
Öğrenci: WESLEY WEI CHIH LIN
Eş Danışman: BARIŞ BİNİCİ, HALUK SUCUOĞLU
Özet:In order to reduce seismic risk in vulnerable buildings, buildings identified to be at risk should be assessed and strengthened. Performance evaluation of deficient buildings has become a major concern due to devastating earthquakes in the past. In order to justify new provisions in design and assessment codes, experiments and analyses are inherently necessary. In this thesis study, investigations into the behaviour of two deficient reinforced concrete frames built at Middle East Technical University’s Structural and Earthquake Laboratory and tested via pseudo-dynamic tests were made. These frames were modelled on the OpenSees platform by following methods of analyses outlined in the Turkish Earthquake Code of 2007 (TEC 2007) and ASCE/SEI-41-06. Both deficient frames were essentially the same, with the only difference being the presence of insufficient lap splices, which was the focus of the study. Time history performance assessments were conducted in accordance to TEC 2007’s damage state limits and ASCE/SEI 41-06’s performance limits. The damages observed matched the performance levels estimated through the procedure outlined in TEC 2007 rather well. Specific to the specimen with lap splice deficiencies, ASCE/SEI 41-06 was overly conservative in its assessments. TEC 2007’s requirements for lap splice lengths were found to be conservative in the laboratory and are able to tolerate deficiencies up to 25% of the required length. With respect to mathematical models, accounting for materials in deficient systems by using nominal but reduced strength properties is not very efficient and unless joint deformations are explicitly accounted for, local deformations cannot be captured.