Yumuşak kilde taş kolonların oturma azaltıcı etkisinin laboratuvar model çalışmaları ile incelenmesi.


Tezin Türü: Yüksek Lisans

Tezin Yürütüldüğü Kurum: Orta Doğu Teknik Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü, Türkiye

Tezin Onay Tarihi: 2012

Tezin Dili: İngilizce

Öğrenci: Mehmet Emrah Sünnetçioğlu

Danışman: MEHMET UFUK ERGUN

Özet:

An experimental study was conducted in order to examine settlement reduction ratios of footing supported by both floating and end bearing type of stone columns. For the floating types, tests were done with varying column lengths of one and two widths of footing (L=B,2B). Tests were conducted in 200 mm* 200 mm* 200 mm cubic loading tanks. The reinforcement effect was achieved by the installation of four stone columns with 20 mm diameter under 70 mm* 70mm model footing. Parameters such as area replacement ratio (a_s), loading plate dimensions, consolidation and vertical pressures applied, and the relative density (D_R) of the granular column were kept constant, the column length (L) was set as the only variable in the experimental tests conducted. In the tests, footing settlements together with subsurface settlements at depths equal to footing width (B) and two times the footing width (2B) were measured by specially designed telltales. The settlement reduction ratios both at surface and subsurface were evaluated in order to determine the effect of column length on settlement improvement. It has been found out that as the column length increases the settlement reduction ratios decrease for all depth intervals. However, there exists a threshold column length (L=2B), beyond which the composite ground demonstrates little settlement improvement.