Design and characterization of small-sized Kiel-type shielded probes
Ankara International Aerospace Conference, AIAC 2025, Ankara, Türkiye, 17 - 19 Eylül 2026, cilt.3271, (Tam Metin Bildiri)
- Yayın Türü: Bildiri / Tam Metin Bildiri
- Cilt numarası: 3271
- Doi Numarası: 10.1088/1742-6596/3271/1/012024
- Basıldığı Şehir: Ankara
- Basıldığı Ülke: Türkiye
- Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
- Orta Doğu Teknik Üniversitesi Adresli: Evet
Özet
This study focuses on the optimization and parameterization of an approximately 3mm diameter Kiel-type (shielded) probe for accurate total pressure measurements to meet an angular insensitivity range of ±45° operating under subsonic flow conditions. The work is motivated by the need for compact, angularly insensitive probes in turbomachinery, where conventional pitot tubes suffer severe accuracy losses at large incidence angles. A literature-based design analysis was combined with stringent manufacturing constraints (e.g., minimum printable wall thickness) to establish a parametric framework for probe geometry. An existing industrial design was analysed for baseline comparison. Using Computational Fluid Dynamics (CFD) simulations with the Reynolds Stress Model (RSM), geometric parameters were studied and optimised to adapt the probe for miniature applications while minimising angular sensitivity. The resulting angular insensitivity obtained from numerical simulations for the optimised probe (Proposed Probe 3) is ±46°. The improved design was manufactured and tested, confirming its reliable performance over a wide angular range with an angular insensitivity value of approximately ±50.5°. This work demonstrates the feasibility of miniaturising Kiel probes while preserving aerodynamic efficiency, and establishes a parametric methodology for tailoring probe geometries to confined applications such as turbomachinery.