Effect of design and operating parameters on the thermal performance of aluminum flat grooved heat pipes


Creative Commons License

Alijani H., Cetin B., Akkuş Y., Dursunkaya Z.

APPLIED THERMAL ENGINEERING, cilt.132, ss.174-187, 2018 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 132
  • Basım Tarihi: 2018
  • Doi Numarası: 10.1016/j.applthermaleng.2017.12.085
  • Dergi Adı: APPLIED THERMAL ENGINEERING
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.174-187
  • Anahtar Kelimeler: Flat plate heat pipe, Grooved wick, Thermal performance, Filling ratio, Dryout, THIN-FILM EVAPORATION, COOLING PERFORMANCE, AL2O3 NANOFLUIDS, WICK, RESISTANCE, MODEL, WATER, ANGLE, FLOW
  • Orta Doğu Teknik Üniversitesi Adresli: Evet

Özet

Four aluminum flat grooved heat pipes with groove widths of 0.2, 0.4, 0.8 and 1.6 mm are fabricated and the effect of filling ratio on the thermal performance is experimentally studied for four different heat flux values of 2.1, 3.2, 4.2 and 5.3 W/cm(2). An optimum filling ratio corresponding to each heat flux is determined where the heat pipe has the best thermal performance. Thermal performance of the heat pipes are evaluated using three indicators: (i) the temperature difference between the heat source and heat sink surfaces, (ii) the temperature difference between the peak system temperature and the temperature of the cooling ambient and (iii) heat pipe effectiveness defined as a temperature difference ratio under dry and operating conditions. A flow and evaporative mass scaling model is developed to interpret the experimental findings. Experimental results reveal that at the optimum point the heat pipe with the 0.4 mm groove width has the best thermal performance, and the heat pipe with the smallest 0.2 mm groove operates under dryout conditions even for the lowest heat flux, the reason of which is discussed based on interpretation of underlying phase change physics. Experiments reveal the existence of two operating regimes: with and without dryout in the grooves. Although higher heat loads can be carried under dryout conditions, a limit exists for the maximum heat flux where the pipe operates without the onset of dryout for a specific groove density. (C) 2017 Elsevier Ltd. All rights reserved.