Design, performance, and calibration of CMS hadron-barrel calorimeter wedges


Abdullin S., Abramov V., Acharya B., Adams M., Akchurin N., Akgun U., ...Daha Fazla

EUROPEAN PHYSICAL JOURNAL C, cilt.55, sa.1, ss.159-171, 2008 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 55 Sayı: 1
  • Basım Tarihi: 2008
  • Doi Numarası: 10.1140/epjc/s10052-008-0573-y
  • Dergi Adı: EUROPEAN PHYSICAL JOURNAL C
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.159-171
  • Orta Doğu Teknik Üniversitesi Adresli: Evet

Özet

Extensive measurements have been made with pions, electrons and muons on four production wedges of the compact muon solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. The energy dependent time slewing effect was measured and tuned for optimal performance.