A hybrid damage assessment for E-and S-glass reinforced laminated composite structures under in-plane shear loading


YILMAZ Ç., Akalin C., Gunal I., Celik H., Buyuk M., Suleman A., ...Daha Fazla

COMPOSITE STRUCTURES, cilt.186, ss.347-354, 2018 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 186
  • Basım Tarihi: 2018
  • Doi Numarası: 10.1016/j.compstruct.2017.12.023
  • Dergi Adı: COMPOSITE STRUCTURES
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.347-354
  • Orta Doğu Teknik Üniversitesi Adresli: Hayır

Özet

Micro-damage initiation and accumulation in two different Glass Fiber Reinforced -E-glass and S-glass-Laminated Composite Structures (LCS) subjected to in-plane shear stressing are monitored with Acoustic Emission (AE) and thermography methods. AE signals caused by micro-damage formation are graphed as a scatter plot of Weighted Peak Frequency (WPF) versus Partial Power 2 (PP2) features and clustered using the K-means algorithm with Bray Curtis dissimilarity function thus resulting in three different well-separated clusters. Each of these clusters corresponds to different micro damages, i.e., transverse cracks, delaminations, or fiber ruptures. It is observed that the E-glass reinforced LCS has higher numbers of AE hits. Thus, the total amount of micro-damage incurred as well as the average temperature change measured by thermography is higher for the E-glass reinforced LCS. It is shown that due to the curing induced residual tensile stress in E-glass reinforced LCS, the initial formation of delamination in E-glass reinforced LCS starts at higher load level. Under the applied shear load, a significant reduction in in-plane shear modulus is observed both for the E-glass and S-glass-reinforced LCS where the E-glass reinforced LCS shows greater reduction. The decrease in in-plane shear modulus is attributed to micro-damage accumulated in the LCS.