Multi-scale high intensity turbulence generator applied to a high pressure turbulent burner
8th International Symposium on Turbulence and Shear Flow Phenomena, TSFP 2013, Poitiers, Fransa, 28 - 30 Ağustos 2013, cilt.1, (Tam Metin Bildiri)
- Yayın Türü: Bildiri / Tam Metin Bildiri
- Cilt numarası: 1
- Basıldığı Şehir: Poitiers
- Basıldığı Ülke: Fransa
- Orta Doğu Teknik Üniversitesi Adresli: Evet
Özet
This study is performed to investigate the interactions between a turbulent flow field and a premixed flame. Comparisons between the turbulence generated by a multi grid turbulence generator and a single grid turbulence generator are made. For this comparison we used the data of Lachaux et al. (2005) for a methane-air premixed flame with an equivalent ratio of 0.6. The turbulence intensity is found to be 40% higher in the isotropic and homogeneous zone of the potential core for the multi grid configuration compared to the single grid configuration. It is also found that the isotropy and homogeneity levels are lower for the multi-grid than for the single grid turbulence generation. Kolmogorov scales are found 2 times lower for a multi grid generation than for a single grid generation at equivalent pressure conditions; Taylor length scales are found lower as well. The effects of multi-scale grid turbulence generation on the premixed turbulent regimes are discussed.