Coating effects of a strain sensor on durability and sensitivity using the fiber loop ringdown spectroscopy technique


Creative Commons License

KAYA B. M., ESENTÜRK O., AŞICI C., Sarac U., DINDIŞ G., BAYKUL M. C.

Physica Scripta, cilt.99, sa.5, 2024 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 99 Sayı: 5
  • Basım Tarihi: 2024
  • Doi Numarası: 10.1088/1402-4896/ad3784
  • Dergi Adı: Physica Scripta
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Aerospace Database, Chemical Abstracts Core, Compendex, INSPEC, zbMATH
  • Anahtar Kelimeler: coated sensors, fiber loop ringdown spectrometer, fiber optic sensors, FLRDS, sensors, single-mode fiber, strain sensor
  • Orta Doğu Teknik Üniversitesi Adresli: Evet

Özet

A sensor region in a single-mode optical fiber loop was created and utilized in order to study the coating effect on sensor durability and system sensitivity by the Fiber Loop Ringdown Spectroscopy (FLRDS) technique. The sensor system was simply designed without any additional optical components. The bending loss theory in the single-mode fiber (SMF) was taken into account in data calculation. After stretching was performed on 10.0 cm long coated and noncoated sensorheads from the mid-points, the strain detection limits were determined as 5.3345 μϵ and 6.7497 μϵ with bare and coated sensorheads, respectively. The purpose of this study is to analyze the effect of N,N-Diethyl-p-phenylenediamine (NDPD) coating of the sensorhead on the sensor durability and sensitivity. The baseline stability of the system was obtained as 1.18% by considering a hundred consecutive data. Regarding to obtained results, the difference between calculated total optical losses of FLRDS systems with noncoated and NDPD coated sensorheads shows that coating sensorhead enhanced the sensor durability and the system sensitivity. An FLRDS system with high sensitivity, simple design and easy setup offers real-time measurement with continuous monitoring and provides advantages on durability by modification the sensorhead such as NDPD coating. Due to its attractive features such as low cost, simplicity, easy setup, high sensitivity, increased durability and continuous monitoring, an FLRDS system has a wide range of application areas in structural health monitoring, transportation, early detection, biomedical, chemical trace elements, rail and asphalt applications for continuous monitoring in a real-time merit.