Microextraction versus exhaustive extraction approaches for simultaneous analysis of compounds in wide range of polarity


Mirnaghi F. S., Gorynski K., Rodriguez-Lafuente A., Boyaci E., Bojko B., Pawliszyn J.

JOURNAL OF CHROMATOGRAPHY A, cilt.1316, ss.37-43, 2013 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 1316
  • Basım Tarihi: 2013
  • Doi Numarası: 10.1016/j.chroma.2013.09.084
  • Dergi Adı: JOURNAL OF CHROMATOGRAPHY A
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.37-43
  • Anahtar Kelimeler: Microextraction, Exhaustive extraction, Solid phase microextraction, Solid phase extraction, Breakthrough volume, SOLID-PHASE MICROEXTRACTION, TANDEM MASS-SPECTROMETRY, PERFORMANCE LIQUID-CHROMATOGRAPHY, THIN-FILM MICROEXTRACTION, BIOLOGICAL-FLUIDS, BINDING, SYSTEM, RECEPTOR, SAMPLES, PLASMA
  • Orta Doğu Teknik Üniversitesi Adresli: Hayır

Özet

This article discusses comparison of microextraction versus exhaustive extraction approaches for simultaneous extraction of compounds in wide range of polarity at low and high volumes of sample by comparing solid phase extraction (SPE) and solid phase microextraction (SPME). Here, both systems are discussed theoretically and evaluated based on experimental data. Experimental comparisons were conducted in terms of extraction recovery, sensitivity, and selectivity for the extraction of doping agent compounds (logP: 0.14-4.98), using C18 as the extraction phase. The extraction recovery of both systems was studied at different volumes of phosphate buffered saline (PBS). The distribution constant of SPME in thin-film geometry (i.e., thin-film microextraction/TFME) as well as the retention factor and breakthrough volume for the SPE system were evaluated for the simultaneous extraction of polar and non-polar compounds. Using 1 mL of sample, the extraction recovery and sensitivity of the SPE system (100 mg sorbent) was comparable with that of TFME format of SPME (15 mg sorbent) for all analytes, with the exception of most polar compounds, due to the smaller amount of the extraction phase in SPME. Breakthrough in the SPE system was observed for more polar compounds in a 25 mL sample; however, this situation did not affect the quantitation of TFME, as this technique operates in equilibrium mode. Experimental values for breakthrough volume were in good match with the calculated theoretical values. Results indicate that the microextraction approach is more suitable for untargeted determinations, where the breakthrough volume cannot be determined prior to the experiment. In addition, when both methods are at optimum conditions, findings suggest that, despite the smaller volume of the extraction phase in TFME, the sensitivity of TFME can exceed that of SPE for samples where the target analytes vary substantially in polarity. (C) 2013 Elsevier B.V. All rights reserved.