Power quality solutions for 12-pulse smelter converters in ETI aluminum works


Ermis M., Acik A., Gultekin B., Terciyanli A., Nalcaci E., Cadirci I., ...Daha Fazla

IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, cilt.40, sa.6, ss.1644-1655, 2004 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 40 Sayı: 6
  • Basım Tarihi: 2004
  • Doi Numarası: 10.1109/tia.2004.836175
  • Dergi Adı: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.1644-1655
  • Orta Doğu Teknik Üniversitesi Adresli: Hayır

Özet

This paper describes the solution of power quality problems arising from 12-pulse smelter converters in the ETI Aluminum Works, Seydisehir, Turkey. The design work is based on practical data collected in the field as well as on the results of detailed simulation studies obtained by EMTDC/PSCAD, SPICE, and MATLAB. The main design objective is to meet both present regulations and harmonic standards by using robust, reliable, and cost-effective systems with a long life expectancy. The shunt-connected passive reactive power compensation system is composed of a damped 11th harmonic filter and a make-up filter tuned to the 5th harmonic with optional damping resistor. Such a system exhibits nearly transient-free switching and series-resonance proof characteristics owing to damping resistors. A close correlation has been obtained between theoretical results and field data.