A HIGH-RESOLUTION TRACKING DETECTOR BASED ON CAPILLARIES FILLED WITH LIQUID SCINTILLATOR


Creative Commons License

ADINOLFI M., ANGELINI C., BAHR J., CARDINI A., CIANFARANI C., DAVIA C., ...Daha Fazla

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, cilt.311, ss.91-97, 1992 (SCI İndekslerine Giren Dergi) identifier identifier

  • Cilt numarası: 311
  • Basım Tarihi: 1992
  • Doi Numarası: 10.1016/0168-9002(92)90853-v
  • Dergi Adı: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
  • Sayfa Sayıları: ss.91-97

Özet

Results are presented on tests in a 5 GeV/c hadron beam of a high-resolution tracking detector constructed from 20-mu-m diameter glass capillaries filled with liquid scintillator. Details are given of the techniques used to eliminate noise in the readout system and to reduce cross-talk between capillaries. A spatial resolution of 15-mu-m is obtained.